How to drain water from an air compressor
Drain water from an air compressor is a key step in daily maintenance. Correct operation can prevent condensate from corroding equipment. The following is a detailed operation guide:
1. Water discharge position
- Bottom of air tank: Usually equipped withBall valve/plug valve, some models haveautomatic drainer。
- oil-gas separator: The water mist filter needs to be checked for non-oil engines, and the accumulated water from the oil-water separator needs to be discharged for oil engines.
2. Water discharge steps
- Stop and reduce pressure
- Turn off the power supply of the air compressor and wait 5-10 minutes for the pressure to drop below 0.2MPa (the pressure gauge pointer is close to zero).
- manual drainage
- Find the drain valve at the bottom of the air tank (refer to the illustration in the manual) and slowly open it with a wrench to avoid water impact.
- drainage time: The valve can be opened for 15-20 seconds for the first time when water is discharged, and subsequently adjusted according to the water quality (dry environment 5 seconds/time).
- Automatic drain maintenance
- Check the electronic drain valve: confirm that the indicator light of the control box is normal, test the drain cycle (usually drain once every 1-2 hours).
- Clean the filter screen: if the drainage is reduced, close the inlet valve and remove the filter screen, and clean it with neutral detergent.
- Special model handling
- oil free compressor: Additional water in the rear cooler needs to be drained to prevent clogging of the dryer.
- water cooled models: Turn off the cooling water circulation first and discharge it from the condensate outlet.
3. Matters needing attention
- security priority: Pressure operation is prohibited! Do not remove the valve until the pressure has been completely relieved.
- environmental adaptation: In humid areas, the frequency of water discharge needs to be increased (once every 30 minutes), and in winter, it is necessary to prevent freezing and bursting of air storage tanks.
- tool to select: Recommended useMagnetic adsorption wrench(Avoid the valve falling), wear an anti-hot cover.
4. Maintenance suggestions
- install the upgrade: Can be installed in high humidity environmentszero-loss drain valve, saves 60% water than ordinary float valves.
- intelligent monitoring: EquippedDew point detector, automatic warning when humidity>60%.
- Quarterly maintenance: Remove the drain valve and check the sealing ring every quarter, and the replacement cycle is 12-18 months.
Typical error cases: A factory did not regularly release water, causing 3 cm thick sludge to accumulate at the bottom of the air storage tank, causing the safety valve to be stuck. It is recommended to formulate an “Air Compressor Water Discharge Record Form” and be signed and confirmed by a special person every day.