How much decibel is the medical air compressor

Noise standards for medical air compressors usually need to be strictly controlled inBelow 60 decibels, to adapt to hospitals, laboratories and other environments that require high silence. Specific standards are as follows:

1. Industry specifications and noise limits

  1. National standard reference
    According to the “GB/T 12348-2008 Code for Determining Noise from Air Compressors”, the noise of industrial equipment needs to be less than 65 decibels, but the requirements for medical scenarios are more stringent and are generally limited toBelow 60 decibels。This standard is similar to that of household air conditioning compressors (about 55 decibels), which ensures a comfortable working environment for medical staff.

  2. Special requirements for medical air compressors
    Some high-end models further reduce noise to a minimum through optimized design and sound insulation technology50-55 decibels。For example:

    • Silent DC motor: Reduce rotating noise.
    • sound-absorbing insulation layer: Block internal noise transmission.
    • damping device: Reduce additional noise caused by vibration.

2. Comparison of noise standards in different scenes

venue type Daytime noise limit Night noise limits remarks
Hospital/Laboratory ≤60 dB Must meet medical equipment mute standards
Nursing area/residential area ≤50 dB ≤40 dB Medical air compressors may exceed the standard
industrial zone ≤70 dB ≤55 dB Applicable standards for ordinary air compressors

3. Noise control technology and selection suggestions

  1. Technology optimization direction
    • structure design: Adopt compact mainframe and efficient sound insulation materials.
    • intelligent control: Reduce load fluctuation noise through frequency conversion adjustment.
    • maintenance measures: Clean the filter regularly and check the shock-absorbing components.
  2. Selection suggestions
    • Small clinic/laboratory: Priority is given to silent models with noise ≤55 decibels.
    • large hospitals: An air compressor with a noise ≤60 decibels and a damping device needs to be selected based on the equipment power and installation location (such as an independent machine room).

IV. Summary

The noise standard for medical air compressors is usuallyBelow 60 decibels, some high-end models can reach 50-55 decibels. When selecting models, we need to focus on silent technology certification (such as the “Medical Silent Oilless Air Compressor” logo) and ensure that equipment installation complies with hospital noise management regulations. For further information on specific models or noise reduction solutions, you can refer to the technical parameters provided by the equipment manufacturer.

Welcome!

Related Articles:
@air
2025-03-18

The oil content of compressed air is probably appropriate.

The appropriate range of compressed air oil content depends on the specific application scenarios and industry requirements, and needs to be comprehensively judged in combination with international standards and application scenarios. The following is an analysis of the key points: 1. International Standard Reference (ISO 8573-1) the standard divides the oil content of compressed air […]

@air
2025-03-07

How much power should the air compressor be?

Selecting the power of the air compressor requires a comprehensive consideration of multiple factors, including the gas consumption volume, working pressure, operating time, pipeline pressure loss, altitude and ambient temperature of the gas equipment. The following are some specific guidance and suggestions: 1. Determine the gas consumption and working pressure of the gas consumption equipment […]

@air
2025-03-05

Pharmaceutical compressed air humidity standard

In the pharmaceutical industry, humidity control of compressed air is crucial because it directly affects the quality and safety of the drug. The humidity standards for compressed air for pharmaceuticals usually involve two aspects: relative humidity and moisture dew point. The specific requirements are as follows: 1. Relative humidity The relative humidity of compressed air […]

@air
2025-03-18

What is the air compressor working continuously?

Air compressor intermittent work may be caused by a variety of reasons, the following are some common reasons and solutions: common Causes leakage of gas path system reason: If there are leakage points in the gas path, such as loose connection parts such as gas pipe joints and valves or damaged seals, it will cause […]

@air
2025-03-07

The difference between power frequency and frequency conversion of air compressor

The main differences between the power frequency and frequency conversion of the air compressor are reflected in the following aspects: 1. Startup characteristics Industry frequency air compressor Startup method: Direct start or star triangle step-down start is usually used. Starting current: The starting current is large, generally 5 to 7 times the rated current, which […]